How District Heating Temperatures Cap Waste-to-Energy Efficiency

The energy efficiency of a waste-to-energy plant depends less on the plant itself than on the heat network it supplies. At the VDI/ITAD Conference, Ramboll showed why Copenhagen’s Amager Bakke reaches 107 per cent. They also showed what stands in the way in Germany.

Waste-to-Energy Plant Amager Bakke in Copenhagen

Key Takeaways

  • District heating temperatures, not plant design, cap waste-to-energy efficiency, says Ramboll.
  • German networks mostly exceed 100 °C supply; Danish third-generation networks stay below 100 °C, with returns under 45 °C.
  • Copenhagen’s Amager Bakke reaches 107 % efficiency via flue gas condensation, heat pumps and storage.
  • Flue gas condensation can lift efficiency by around 20 %, but needs low network temperatures.
  • Operators should join heat planning and push for lower temperatures.

The temperature of district heating networks is the central factor for the energy efficiency of waste-to-energy plants. This was the main message of Raphael Röcken, Business Development Manager at the engineering company Ramboll, at the 33rd VDI/ITAD Conference on 22 September 2026. “You can build the best plant imaginable – without a corresponding district heating network, you will always be limited in what you can deliver from the plant,” Röcken said.

Technical measures inside the plant can increase efficiency, he explained, but their effect depends on whether the heat can be used. German district heating networks typically belong to the second generation, with supply temperatures above 100 degrees Celsius and return temperatures below 70 degrees Celsius. Additionally, third-generation networks, common in Denmark, operate with supply temperatures below 100 degrees Celsius and return temperatures below 45 degrees Celsius.

Low Temperatures Unlock Waste Heat

With low network temperatures, the potential for delivering district heat from a waste-to-energy plant is high. A larger share of the heat can be supplied directly from waste heat, for example through flue gas condensation. Power generation also remains high, as lower steam parameters are needed to reach the supply temperature. However, with high network temperatures, heat has to be produced largely from turbine steam, and power generation falls. At temperatures of 70 and 110 degrees Celsius, the loss amounts to around 0.17 megawatts of electricity per megawatt of district heat.

Röcken used Amager Bakke in Copenhagen, Denmark, as an example of what is technically possible. The plant produces live steam at 70 bar and 440 degrees Celsius and uses a back-pressure turbine, as heat offtake is guaranteed all year round. Notably, a two-stage flue gas condensation cools the flue gas to around 40 degrees Celsius, supported by heat pumps. The plant also has a heat storage facility of 22,000 cubic metres.

Measured against the lower heating value of the waste, Amager Bakke reaches an efficiency of 107 per cent. Values above 100 per cent are possible because the efficiency of waste-to-energy plants is usually referenced to the lower heating value. In addition, the condensation energy contained in the flue gas can also be recovered. “That is only possible because we have the corresponding district heating temperatures,” Röcken said.

Amager Bakke: 400,000 Tonnes a Year

Amager Bakke went into operation in 2017. It is owned by Amager Resource Center (ARC), an inter-municipal company, and treats around 400,000 tonnes of waste a year on two lines. According to ARC, each tonne of waste yields 2.7 megawatt hours of district heating and 0.8 megawatt hours of electricity. The plant can supply up to 63 megawatts of electricity and up to 247 megawatts of district heating. Heat pumps in the flue gas cleaning system account for around 20 per cent of its district heating production.

The plant is also known for the artificial ski slope on its roof, designed by the architecture firm Bjarke Ingels Group. Ramboll has advised ARC as owner’s engineer on the project.

Flue Gas Condensation Delivers the Largest Gain

For an example plant with a firing capacity of 160 megawatts, Röcken compared two ways of recovering heat from flue gas. A flue gas heat exchanger that cools the gas by 30 kelvin, from 130 to 100 degrees Celsius, recovers around 3.5 megawatts. This raises the plant’s energy efficiency by around 2 per cent and also works with high district heating temperatures.

Flue gas condensation over the same temperature difference recovers around 35 megawatts. In this process, the flue gas is first saturated with water at around 65 degrees Celsius and then cooled further, releasing the condensation energy. This raises the efficiency by around 20 per cent – but requires a district heating network with suitable temperatures.

Further gains are possible on the steam side. Lowering the flue gas temperature after the boiler from 180 to 160 degrees Celsius and reducing the oxygen content in the flue gas from 7.2 to 3.9 per cent each raise electrical efficiency by around 2 per cent. Moreover, higher live steam parameters than the common 40 bar and 400 degrees Celsius, as well as reheating, increase power output further. The AVI plant in Amsterdam, with a capacity of 840,000 tonnes per year, operates at 440 degrees Celsius and 130 bar. After the first turbine stage, the steam is reheated from 200 to 320 degrees Celsius at 15 bar. The plant reaches a net electrical efficiency of 30.5 per cent.

Turbine Choice Depends on Summer Heat Demand

The choice of turbine depends on how much heat can be sold throughout the year. A back-pressure turbine is suitable if high heat offtake is guaranteed all year round. In an example project with 50 megawatts of district heating, it produced around 10 instead of 7 megawatts of electricity – around 40 per cent more. Many plants, however, can deliver little or no heat for several months in summer. In that case, an extraction-condensing turbine is the more suitable option, possibly with a low-pressure section that can be decoupled. Lower exhaust and extraction steam parameters also increase power generation.

Flue gas recirculation, in which around 15 per cent of the flue gas is returned to the furnace instead of secondary air, reduces excess air and flue gas volume. This cuts thermal losses through the stack and raises the CO2 concentration in the flue gas. According to Röcken, this is relevant for carbon capture, as its specific energy demand depends strongly on CO2 concentration. In flue gas cleaning, he recommended SCR systems in the raw gas instead of tail-end systems to avoid reheating and pressure losses. Spray dryers destroy exergy; semi-dry systems are therefore preferable from an energy perspective.

Storage and Carbon Capture

Heat storage increases the amount of heat delivered from waste-to-energy plants and reduces fossil peak-load generation. Steel tanks such as the two 24,000-cubic-metre tanks at Avedøre near Copenhagen buffer heat for hours to days. Pit storage, such as the 200,000-cubic-metre facility in Vojens, shifts heat over weeks to months. Storage also allows power and heat production to be partly decoupled.

Battery storage in containers with 4 to 9 megawatt hours of capacity can serve as emergency power and for grid services, as at EEW’s plant in Premnitz with 15 megawatt hours and 7 megawatts. At around 100 euros per megawatt hour of electricity, however, it costs more than heat storage and has a smaller effect on the plant’s energy balance.

According to Röcken, carbon capture does not necessarily reduce overall efficiency. Amine-based capture requires large amounts of steam, which reduces power output, and raises the plant’s own electricity consumption. The energy used, however, is released again as waste heat. If district heating temperatures are not too high, this heat can be used and heat supply maintained. The lost electricity cannot be recovered.

Operators Urged to Join Heat Planning

Röcken called on waste-to-energy operators to become part of district heating planning and to push for lower network temperatures and priority for their waste heat. He criticised situations in which a river heat pump preheats district heating water from 60 to 70 degrees Celsius while a nearby plant releases flue gas at 130 degrees Celsius through its stack.

Copenhagen has lowered its supply and return temperatures, and cities in Switzerland and Germany are working on similar steps. Operators should be involved in these decisions rather than simply be told how much heat they can deliver, he said.

AI search

Ask WtE Monitor

Answers come only from WtE Monitor articles and plant data, with sources. Ask in any language.

Your question is processed by Anthropic to generate the answer. Please do not enter personal data. Privacy policy

3 questions a month with a free subscription, unlimited with WtE Monitor+. Subscribe free · Get WtE Monitor+


Discover more from WtE Monitor

Subscribe to get the latest posts sent to your email.

Free newsletter

Waste-to-energy news, straight to your inbox.

Projects, policy and plant data from across Europe. Get every story as it is published, or switch to a daily or weekly digest.

Free. Confirm by email. Change the frequency or unsubscribe at any time.

Leave a Reply